For intelligent monitoring PDU, please send your inquiry at sales@avanix.com.cn for products pictures, features and prices. We only offer OEM/ODM on intelligent monitoring PDUs.
Function | Function description | Performance parameter | F series | K series | remarks | |||||||
1 | 2 | 3 | 4 | 1 | 2 | 3 | 4 | |||||
Working power supply voltage | Voltage required for normal operation of the product | 90~250VAC 50/60Hz | √ | √ | √ | √ | √ | √ | √ | √ | ||
Access interface | network | Access monitoring via Ethernet or LAN | 10/100Mb network adaptation | √ | √ | √ | √ | |||||
Serial port | Access control through serial port | RJ45 Interface(RS485) | √ | √ | √ | √ | √ | √ | √ | √ | ||
Peripheral Interface | Sensor interface | USB Interface (RS485, one out of two interface with temperature and humidity) | √ | √ | √ | √ | ||||||
Peripheral Interface | Temperature and humidity interface | USB interface (IIC, one out of two with sensor interface) | √ | √ | √ | √ | √ | √ | √ | √ | default | |
Access mode | WEB | Browser access | Compatible with ie, Firefox and other mainstream kernel browsers, support 256 bit encryption | √ | √ | √ | √ | |||||
TELNET | Simple command line access | / | √ | √ | √ | √ | ||||||
SSH | Encrypted command line access | Support for sshv2 version | √ | √ | √ | √ | ||||||
SNMP | Support common simple network management protocol centralized monitoring | Compatible with V1, V2, V3 and other protocol versions | √ | √ | √ | √ | ||||||
RS485 | MODBUS RTU protocol | / | √ | √ | √ | √ | √ | √ | √ | √ | ||
Operating System compatibility | Support multiple operating systems | The monitoring terminal is compatible with win7 / win10 / Linux and other mainstream operating systems | √ | √ | √ | √ | ||||||
Protocol customization | For customer system integration | Development protocol Telnet, SSH, SNMP, etc | √ | √ | √ | √ | ||||||
RS485 | Customized according to customer agreement | √ | √ | √ | √ | √ | √ | √ | √ | |||
Software upgrade | Software upgrade | Support for software updates | √ | √ | √ | √ | ||||||
Control | Control each output on-off | Breaking capacity of each output 16A 250VAC | √ | √ | √ | √ | ||||||
Power on and power off in sequence | The time interval of sequential power off is 1 s, and the time interval of sequential power on is 1 ~ 60 s, which can be set to prevent the electric equipment from starting the interference equipment at the same time, polluting the line and failing to close the main switch of the line | √ | √ | √ | √ | |||||||
Time switch | Output bit timing switch | √ | √ | |||||||||
Output bit power off hold | The output bit remains in the on / off state before power failure | √ | √ | √ | √ | |||||||
Monitor | Detect the status of each output fuse | It can monitor whether the fuse is off or the output switch cannot be turned on or off normally | √ | √ | √ | √ | √ | √ | Optional | |||
Monitoring input voltage | Resolution: 0.1V; Accuracy: ± 1% +1 word Range: 90-350v | √ | √ | √ | √ | √ | √ | √ | √ | |||
Monitor the total input and output current | Resolution: 0.01A; Accuracy: ± 1% + 1 word Range: 0.01 ~ 70A | √ | √ | √ | √ | √ | √ | √ | √ | |||
Monitoring total active power | Resolution: 1W; Accuracy: ± 2% | √ | √ | √ | √ | √ | √ | √ | √ | |||
Monitoring total power factor | Resolution: 0.001; Accuracy: ± 2% | √ | √ | √ | √ | √ | √ | √ | √ | |||
Monitoring total electric energy | Resolution: 0.1kwh; Grade: 1 | √ | √ | √ | √ | √ | √ | √ | √ | |||
Monitor each output current | Resolution: 0.01A; Accuracy: ± 1% + 1 wordRange: 0.1 ~ 20A | √ | √ | √ | √ | |||||||
Monitor each output active power | Resolution: 1W; Accuracy: ± 2% | √ | √ | √ | √ | |||||||
Monitor each output power factor | Resolution: 0.001; Accuracy: ± 2% | √ | √ | √ | √ | |||||||
Monitor each output energy | Resolution: 0.1kwh; Grade: 1 | √ | √ | √ | √ | |||||||
Monitoring ambient temperature | Resolution: 0.1 ℃; Accuracy: ± 0.5 ℃ Range range: -40-80 ℃ | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Monitoring of environmental humidity | Resolution: 1%; Accuracy: ± 3% RH Range: 01-99% | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Monitoring of environmental smoke | Effective for maximum 25 m² | √ | √ | √ | √ | Optional | ||||||
Monitoring environmental water immersion | Monitoring of dripping and water immersion environment | √ | √ | √ | √ | Optional | ||||||
Infrared monitoring environment personnel entering | Maximum detection distance 11m | √ | √ | √ | √ | Optional | ||||||
Door and window opening monitoring | Minimum opening distance 5mm effective | √ | √ | √ | √ | Optional | ||||||
Surge prevention and lightning protection failure monitoring | Failure does not affect the normal use of the product | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Alarm limit | Total voltage limit | Rationality of automatic identification limit | √ | √ | √ | √ | √ | √ | √ | √ | ||
Total current limit | Rationality of automatic identification limit | √ | √ | √ | √ | √ | √ | √ | √ | |||
Each output current limit | Rationality of automatic identification limit | √ | √ | √ | √ | |||||||
Environmental temperature limit | Rationality of automatic identification limit | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Environmental humidity limit | Rationality of automatic identification limit | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Alarm output, monitoring and query | Total voltage alarm | Over upper and lower limit alarm, alarm output sound and light, dry contact, local monitoring query, the following PS series no (email, can be monitored and queried by web, SNMP, telnet / SSH) | √ | √ | √ | √ | √ | √ | √ | √ | ||
Total current alarm | Over upper and lower limit alarm, alarm output sound and light, dry contact, local monitoring query, the following PS series no (email, can be monitored and queried by web, SNMP, telnet / SSH) | √ | √ | √ | √ | √ | √ | √ | √ | |||
Total current level 2 alarm | Over rated current alarm | √ | √ | √ | √ | √ | √ | √ | √ | |||
Each output current alarm | Over upper and lower limit alarm, alarm output sound and light, dry contact, local monitoring query, the following PS series no (email, can be monitored and queried by web, SNMP, telnet / SSH) | √ | √ | √ | √ | |||||||
Each current level 2 alarm | Alarm of exceeding the rated current of output bit | √ | √ | √ | √ | |||||||
Ambient temperature alarm | Over upper and lower limit alarm, alarm output sound and light, dry contact, local monitoring query, the following PS series no (email, can be monitored and queried by web, SNMP, telnet / SSH) | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Ambient humidity alarm | Over upper and lower limit alarm, alarm output sound and light, dry contact, local monitoring query, the following PS series no (email, can be monitored and queried by web, SNMP, telnet / SSH) | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Ambient smoke alarm | Over upper and lower limit alarm, alarm output sound and light, dry contact, local monitoring query, the following PS series no (email, can be monitored and queried by web, SNMP, telnet / SSH) | √ | √ | √ | √ | Optional | ||||||
Environmental flooding alarm | Over upper and lower limit alarm, alarm output sound and light, dry contact, local monitoring query, the following PS series no (email, can be monitored and queried by web, SNMP, telnet / SSH) | √ | √ | √ | √ | Optional | ||||||
Personnel entry warning | The alarm outputs email and SMS, which can be monitored and queried by web, SNMP and telnet / SSH | √ | √ | √ | √ | Optional | ||||||
Door and window alarm | The alarm outputs email and SMS, which can be monitored and queried by web, SNMP and telnet / SSH | √ | √ | √ | √ | Optional | ||||||
Open circuit alarm of circuit breaker | Alarm output sound and light, dry contact, local monitoring query, the following PS series no (e-mail, SMS, web, SNMP, telnet / SSH monitoring query) | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Surge protection and lightning protection failure alarm | Alarm output sound and light, dry contact, local monitoring query, the following PS series no (e-mail, SMS, web, SNMP, telnet / SSH monitoring query) | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Display, indication | Output indicator | Each output has an indicator light | √ | √ | √ | √ | ||||||
LCD display | Display current and voltage, query and display product information and alarm information | √ | √ | √ | √ | √ | √ | √ | √ | |||
Key menu operation | Query information | Query and display product information, alarm information, current, etc | √ | √ | √ | √ | √ | √ | √ | √ | ||
On / off alarm sound, dry contact | Turn off / turn on the alarm sound and dry contact output. The dry contact output has two options: normally open and normally closed. The passive contact can be connected to 2A 250VAC | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Protect | Lightning protection and surge protection | Differential mode: ± 2KV; Common mode: ± 2KV Flow rate: 3KA; Maximum discharge current: 5KA | √ | √ | √ | √ | √ | √ | √ | √ | ||
Each with safety tube | The breaking force of the safety pipe is 1500A; To prevent power failure of main line and disaster of power equipment and lines, the safety pipe can be equipped with 0.1-16a | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Breaker protection | It is used for switching product power supply, preventing short circuit from affecting main line, preventing overload of power equipment from disasters, breaking force of 6000a | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Recoverable overload protection | Prevent the overload of power equipment from disasters | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Record | Alarm log | Cycle alarm record log, which can be queried, exported and saved, and deleted | √ | √ | √ | √ | ||||||
Operation log | Can be exported to view and delete | √ | √ | √ | √ | |||||||
Administration | User management | Distinguish the authority of administrator and general staff | √ | √ | √ | √ | ||||||
Clock synchronization | NTP network time synchronization | √ | √ | √ | √ | |||||||
Intelligent recognition | Intelligent recognition output | Automatic identification of output mode and digit | √ | √ | √ | √ | √ | √ | √ | √ | ||
Intelligent recognition sensor | The sensor interface does not need to be defined, and the type and number of sensors can be identified by access | √ | √ | √ | √ | √ | √ | √ | √ | |||
Intelligent recognition limits | When the setting limit is out of range, the setting is invalid | √ | √ | √ | √ | √ | √ | √ | √ | |||
The maximum output current of intelligent identification product and the power of current product accessible equipment | √ | √ | √ | √ | ||||||||
1 ~ 8 sensors / class access | Simultaneous access of multiple types and sensors | Sensor access, expansion and selection are flexible, and new sensors can be designed according to customers' new requirements | √ | √ | √ | √ | Optional | |||||
Connection | K and k connection | Ethernet interface, hand in hand cascade | √ | √ | √ | √ | ||||||
F and F connection | RS485 bus | √ | √ | √ | √ | √ | √ | √ | √ |
For intelligent monitoring PDU, please send your inquiry at sales@avanix.com.cn for products pictures, features and prices. We only offer OEM/ODM on intelligent monitoring PDUs.
Function | Function description | Performance parameter | F series | K series | remarks | |||||||
1 | 2 | 3 | 4 | 1 | 2 | 3 | 4 | |||||
Working power supply voltage | Voltage required for normal operation of the product | 90~250VAC 50/60Hz | √ | √ | √ | √ | √ | √ | √ | √ | ||
Access interface | network | Access monitoring via Ethernet or LAN | 10/100Mb network adaptation | √ | √ | √ | √ | |||||
Serial port | Access control through serial port | RJ45 Interface(RS485) | √ | √ | √ | √ | √ | √ | √ | √ | ||
Peripheral Interface | Sensor interface | USB Interface (RS485, one out of two interface with temperature and humidity) | √ | √ | √ | √ | ||||||
Peripheral Interface | Temperature and humidity interface | USB interface (IIC, one out of two with sensor interface) | √ | √ | √ | √ | √ | √ | √ | √ | default | |
Access mode | WEB | Browser access | Compatible with ie, Firefox and other mainstream kernel browsers, support 256 bit encryption | √ | √ | √ | √ | |||||
TELNET | Simple command line access | / | √ | √ | √ | √ | ||||||
SSH | Encrypted command line access | Support for sshv2 version | √ | √ | √ | √ | ||||||
SNMP | Support common simple network management protocol centralized monitoring | Compatible with V1, V2, V3 and other protocol versions | √ | √ | √ | √ | ||||||
RS485 | MODBUS RTU protocol | / | √ | √ | √ | √ | √ | √ | √ | √ | ||
Operating System compatibility | Support multiple operating systems | The monitoring terminal is compatible with win7 / win10 / Linux and other mainstream operating systems | √ | √ | √ | √ | ||||||
Protocol customization | For customer system integration | Development protocol Telnet, SSH, SNMP, etc | √ | √ | √ | √ | ||||||
RS485 | Customized according to customer agreement | √ | √ | √ | √ | √ | √ | √ | √ | |||
Software upgrade | Software upgrade | Support for software updates | √ | √ | √ | √ | ||||||
Control | Control each output on-off | Breaking capacity of each output 16A 250VAC | √ | √ | √ | √ | ||||||
Power on and power off in sequence | The time interval of sequential power off is 1 s, and the time interval of sequential power on is 1 ~ 60 s, which can be set to prevent the electric equipment from starting the interference equipment at the same time, polluting the line and failing to close the main switch of the line | √ | √ | √ | √ | |||||||
Time switch | Output bit timing switch | √ | √ | |||||||||
Output bit power off hold | The output bit remains in the on / off state before power failure | √ | √ | √ | √ | |||||||
Monitor | Detect the status of each output fuse | It can monitor whether the fuse is off or the output switch cannot be turned on or off normally | √ | √ | √ | √ | √ | √ | Optional | |||
Monitoring input voltage | Resolution: 0.1V; Accuracy: ± 1% +1 word Range: 90-350v | √ | √ | √ | √ | √ | √ | √ | √ | |||
Monitor the total input and output current | Resolution: 0.01A; Accuracy: ± 1% + 1 word Range: 0.01 ~ 70A | √ | √ | √ | √ | √ | √ | √ | √ | |||
Monitoring total active power | Resolution: 1W; Accuracy: ± 2% | √ | √ | √ | √ | √ | √ | √ | √ | |||
Monitoring total power factor | Resolution: 0.001; Accuracy: ± 2% | √ | √ | √ | √ | √ | √ | √ | √ | |||
Monitoring total electric energy | Resolution: 0.1kwh; Grade: 1 | √ | √ | √ | √ | √ | √ | √ | √ | |||
Monitor each output current | Resolution: 0.01A; Accuracy: ± 1% + 1 wordRange: 0.1 ~ 20A | √ | √ | √ | √ | |||||||
Monitor each output active power | Resolution: 1W; Accuracy: ± 2% | √ | √ | √ | √ | |||||||
Monitor each output power factor | Resolution: 0.001; Accuracy: ± 2% | √ | √ | √ | √ | |||||||
Monitor each output energy | Resolution: 0.1kwh; Grade: 1 | √ | √ | √ | √ | |||||||
Monitoring ambient temperature | Resolution: 0.1 ℃; Accuracy: ± 0.5 ℃ Range range: -40-80 ℃ | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Monitoring of environmental humidity | Resolution: 1%; Accuracy: ± 3% RH Range: 01-99% | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Monitoring of environmental smoke | Effective for maximum 25 m² | √ | √ | √ | √ | Optional | ||||||
Monitoring environmental water immersion | Monitoring of dripping and water immersion environment | √ | √ | √ | √ | Optional | ||||||
Infrared monitoring environment personnel entering | Maximum detection distance 11m | √ | √ | √ | √ | Optional | ||||||
Door and window opening monitoring | Minimum opening distance 5mm effective | √ | √ | √ | √ | Optional | ||||||
Surge prevention and lightning protection failure monitoring | Failure does not affect the normal use of the product | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Alarm limit | Total voltage limit | Rationality of automatic identification limit | √ | √ | √ | √ | √ | √ | √ | √ | ||
Total current limit | Rationality of automatic identification limit | √ | √ | √ | √ | √ | √ | √ | √ | |||
Each output current limit | Rationality of automatic identification limit | √ | √ | √ | √ | |||||||
Environmental temperature limit | Rationality of automatic identification limit | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Environmental humidity limit | Rationality of automatic identification limit | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Alarm output, monitoring and query | Total voltage alarm | Over upper and lower limit alarm, alarm output sound and light, dry contact, local monitoring query, the following PS series no (email, can be monitored and queried by web, SNMP, telnet / SSH) | √ | √ | √ | √ | √ | √ | √ | √ | ||
Total current alarm | Over upper and lower limit alarm, alarm output sound and light, dry contact, local monitoring query, the following PS series no (email, can be monitored and queried by web, SNMP, telnet / SSH) | √ | √ | √ | √ | √ | √ | √ | √ | |||
Total current level 2 alarm | Over rated current alarm | √ | √ | √ | √ | √ | √ | √ | √ | |||
Each output current alarm | Over upper and lower limit alarm, alarm output sound and light, dry contact, local monitoring query, the following PS series no (email, can be monitored and queried by web, SNMP, telnet / SSH) | √ | √ | √ | √ | |||||||
Each current level 2 alarm | Alarm of exceeding the rated current of output bit | √ | √ | √ | √ | |||||||
Ambient temperature alarm | Over upper and lower limit alarm, alarm output sound and light, dry contact, local monitoring query, the following PS series no (email, can be monitored and queried by web, SNMP, telnet / SSH) | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Ambient humidity alarm | Over upper and lower limit alarm, alarm output sound and light, dry contact, local monitoring query, the following PS series no (email, can be monitored and queried by web, SNMP, telnet / SSH) | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Ambient smoke alarm | Over upper and lower limit alarm, alarm output sound and light, dry contact, local monitoring query, the following PS series no (email, can be monitored and queried by web, SNMP, telnet / SSH) | √ | √ | √ | √ | Optional | ||||||
Environmental flooding alarm | Over upper and lower limit alarm, alarm output sound and light, dry contact, local monitoring query, the following PS series no (email, can be monitored and queried by web, SNMP, telnet / SSH) | √ | √ | √ | √ | Optional | ||||||
Personnel entry warning | The alarm outputs email and SMS, which can be monitored and queried by web, SNMP and telnet / SSH | √ | √ | √ | √ | Optional | ||||||
Door and window alarm | The alarm outputs email and SMS, which can be monitored and queried by web, SNMP and telnet / SSH | √ | √ | √ | √ | Optional | ||||||
Open circuit alarm of circuit breaker | Alarm output sound and light, dry contact, local monitoring query, the following PS series no (e-mail, SMS, web, SNMP, telnet / SSH monitoring query) | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Surge protection and lightning protection failure alarm | Alarm output sound and light, dry contact, local monitoring query, the following PS series no (e-mail, SMS, web, SNMP, telnet / SSH monitoring query) | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Display, indication | Output indicator | Each output has an indicator light | √ | √ | √ | √ | ||||||
LCD display | Display current and voltage, query and display product information and alarm information | √ | √ | √ | √ | √ | √ | √ | √ | |||
Key menu operation | Query information | Query and display product information, alarm information, current, etc | √ | √ | √ | √ | √ | √ | √ | √ | ||
On / off alarm sound, dry contact | Turn off / turn on the alarm sound and dry contact output. The dry contact output has two options: normally open and normally closed. The passive contact can be connected to 2A 250VAC | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Protect | Lightning protection and surge protection | Differential mode: ± 2KV; Common mode: ± 2KV Flow rate: 3KA; Maximum discharge current: 5KA | √ | √ | √ | √ | √ | √ | √ | √ | ||
Each with safety tube | The breaking force of the safety pipe is 1500A; To prevent power failure of main line and disaster of power equipment and lines, the safety pipe can be equipped with 0.1-16a | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Breaker protection | It is used for switching product power supply, preventing short circuit from affecting main line, preventing overload of power equipment from disasters, breaking force of 6000a | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Recoverable overload protection | Prevent the overload of power equipment from disasters | √ | √ | √ | √ | √ | √ | √ | √ | Optional | ||
Record | Alarm log | Cycle alarm record log, which can be queried, exported and saved, and deleted | √ | √ | √ | √ | ||||||
Operation log | Can be exported to view and delete | √ | √ | √ | √ | |||||||
Administration | User management | Distinguish the authority of administrator and general staff | √ | √ | √ | √ | ||||||
Clock synchronization | NTP network time synchronization | √ | √ | √ | √ | |||||||
Intelligent recognition | Intelligent recognition output | Automatic identification of output mode and digit | √ | √ | √ | √ | √ | √ | √ | √ | ||
Intelligent recognition sensor | The sensor interface does not need to be defined, and the type and number of sensors can be identified by access | √ | √ | √ | √ | √ | √ | √ | √ | |||
Intelligent recognition limits | When the setting limit is out of range, the setting is invalid | √ | √ | √ | √ | √ | √ | √ | √ | |||
The maximum output current of intelligent identification product and the power of current product accessible equipment | √ | √ | √ | √ | ||||||||
1 ~ 8 sensors / class access | Simultaneous access of multiple types and sensors | Sensor access, expansion and selection are flexible, and new sensors can be designed according to customers' new requirements | √ | √ | √ | √ | Optional | |||||
Connection | K and k connection | Ethernet interface, hand in hand cascade | √ | √ | √ | √ | ||||||
F and F connection | RS485 bus | √ | √ | √ | √ | √ | √ | √ | √ |